[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Little Giant Pumps
The trick to getting an even flow is to keep it symetrical, and to have
a restrictor per camera that determines the flow. A one to two split,
with another in each branch does nicely. If you do get a blockage,
then a camera will get starved, but if in series, they all will, and
it will hit the downstream units far more because of the Peltiers.
--
Paul Repacholi 1 Crescent Rd.,
+61 (08) 9257-1001 Kalamunda.
West Australia 6076
Raw, Cooked or Well-done, it's all half baked.