[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Mark IV reduction pipeline, release 0.2



Michael Sallman wrote:
> 
> Stupendous Man wrote:
> >
> >   If you do run the code on these test images, compare your final result
> > to mine.  I find a photometric solution (in file Mhra2011797.coeff)
> >
> >     V=V,(V-I)  N    166  a  -8.603  0.032  b  -0.182  0.029   RMS  0.124
> >     I=I,(I-V)  N    166  a  -8.258  0.024  b  -0.036  0.021   RMS  0.102
> 
> Michael,
> (...)
> Me too.
> It took about 66 minutes on my computer (Celeron 333, 256MB memory)
>
 I finally got it to run all the way to the end, and I got the same result.
44 minutes on a Pentium 450, 256MB. Red Hat 6.2.
 
> >   Comments, suggestions, bug reports, fixes are all welcome.

 The last gotcha for me was long directory names. When I replaced 
"/data/TASS/Disk18subset/output" with "/TD/output" it ran to completion; before 
I did that, it died trying to exec the collate program. I presume this is some
TCL buffer size restriction.

 I agree with what Tom said - very nice job of documentation.